Распределитель тепла допримо 3 монтаж

Содержание
  1. We help people to contribute to climate protection.
  2. We develop new technologies with our customers and partners.
  3. To achieve this, we manage data and processes that make the building climate-friendly, safe and comfortable.
  4. Content World
  5. ESG-linked financing explained in simple terms: four questions to the CFO
  6. Momentum for ambitious CO2 targets: ista concludes second ESG-linked financing of some 450 million euros
  7. Circular economy: a second life for devices
  8. COVID 19 pandemic: ista has taken numerous actions
  9. With us, residents in buildings save energy, costs and CO2 emissions.
  10. Career at ista
  11. Solutions
  12. Sustainability
  13. Распределитель затрат отопления допримо 3 радио счётчик распределитель тепловой энергии
  14. Для распределения расходов тепла между жильцами в ТСЖ и УК с централизованными системами отопления используются электронные распределители последнего поколения, предназначенные для распределение тепловой энергии и денежные затраты в квартирах. К вашим услугам счётчик пропорционатор . Распределение расходов на одну квартиру- дом производится с помощью специализированной программы. Использование распределителей затрат на отопление представляется более дешевой альтернативой теплосчётчиков, установленных на подводе к каждому обогревательному прибору и смонтированному в трубопровод в виде расходомера и термостопротивления. Описание Ista Doprimo-это электронный распределитель затрат на отопление, который работает посредством разницы показаний датчиков температуры отопления на элементе обогрева (радиаторе), и температуре окружающей среды (комнатный датчик) . Датчик температуры окружающей среды позволяет учесть тепловую энергию только после определенной температуры, установленный порог превышен. Корпус устройства выполнен из пластика устойчивого к высоким температурам. Она содержит электронные дисплей- многофункциональный ЖК-экран, аккумулятор, и датчики температуры. Оптический порт предназначен для обмена с контроллером и монтируется на на передней стороне распределителя. Тепловой контакт с радиатором обеспечивается через тепловой адаптер из алюминия, на который монтируется счётчик распределитель тыльной стороной. Счётчик распределитель крепится на радиатор с помощью комплекта монтажных элементов, так чтобы был обеспечен хороший кон такт между ними. Распределитель тепловой энергии при монтаже пломбируется. Распределитель затрат тепла позволяет избежать ошибочных показаний расхода из-за случайного обогрева различной природы. Электронный распределитель может быть запрограммирован с помощью оптического датчика и персонального компьютера или с помощью переносного программатора через оптический порт. Программируются следующие величины: — серийный номер; — M-bus адрес; — пароль; — K-коэффициент на вид прибора и размер; — Дата и время
  15. Преимущества ista doprimo 3 radio danfoss x-10v: indiv-10, он соответствует EN 834, 2-датчика температуры, Дистанционное обслуживание датчика (по запросу), Радио системы 868 МГц беспроводной M-BUS в соответствии с EN 13757-4, Этот стандартный протокол позволяет использовать несколько радиоприемных устройств, доступных на рынке, при условии, что они находятся в соответствии с действующими нормативами, Стационарные или переменной scale (большая библиотека поправочных коэффициентов К, Оптический интерфейс для настройки параметров и загрузки данных, AES-128 шифрования для безопасной передачи данных (включено), Защита от вскрытия и внешних источников тепла, можно включать и настраивать летний режим, 10 лет эксплуатации без обслуживания.
  16. Чем отличается тепловой счетчик от распределителя затрат на отопление допримо 3
Читайте также:  Схема монтажа hettich направляющие скрытого монтажа quadro

We help people to contribute to climate protection.

With all our energy.

We develop new technologies with our customers and partners.

With all our energy.

To achieve this, we manage data and processes that make the building climate-friendly, safe and comfortable.

Our data-based products and services make individual energy consumption transparent to residents so they can save energy, costs and CO2. This in turn makes it easier for the owner to achieve climate protection targets and increases the energy efficiency and therefore the value of the property. So residents and owners together actively contribute to climate protection.

Content World

ESG-linked financing explained in simple terms: four questions to the CFO

Momentum for ambitious CO2 targets: ista concludes second ESG-linked financing of some 450 million euros

Circular economy: a second life for devices

COVID 19 pandemic: ista has taken numerous actions

«We take responsibility, promote trust, keep commitments, empower our employees and build partnerships.”

These five values determine our actions as a company and their significance has become even more important now, in this time of a global emergency caused by COVID-19.

Two things are our top priority: the health of our employees, customers, suppliers and partners and the fulfilment of our performance promise to our customers. This is why ista has implemented numerous safety measures and is constantly adapting them to the current conditions.

We see it as our responsibility to support the containment of the virus to the best of our ability. Accordingly, we have issued comprehensive rules and instructions on behavior and hygiene to our employees and service partners. In addition, we have rapidly changed our working methods. A large number of our employees now work from home. We are fully accessible and able to work. If necessary, our numerous locations and employees in Germany and abroad enable us to provide our services, such as the billing of heating costs, even across locations. In addition, many of our processes are digitalized and are therefore hardly affected by the current developments.

Читайте также:  Монтаж системы противодымной защиты

Appointments are currently carried out by our service partners and technicians on site at our customers’ premises. Of course they pay attention to the necessary distance and hygiene rules. If customers or residents do not wish to make appointments on site due to the current situation, we fully understand this and will arrange a new appointment in due course.

Our service and delivery capacity is currently secured. However, we cannot rule out the possibility that there will be delays and restrictions in our company as well. The far-reaching requirements and rules of the German government have an impact — also on our everyday business. As a long-standing and reliable partner of the real estate industry, it is our goal to process our customers’ orders in the customary quality and within the agreed time.

Thank you for your trust.

Your ista International GmbH

With us, residents in buildings save energy, costs and CO2 emissions.

Our core product, data-based heat cost allocation, helps residents of multi-family buildings to save in average 20 % of their annual heat consumption and costs. Every year some 3.7 million tonnes of CO2 emissions are avoided by our customers in Germany alone.

Career at ista

A dynamic, growing market, a supportive Top Employer and a diverse range of fulfilling roles await you at ista, a global market player that makes buildings climate-friendly, safe and comfortable.

Solutions

With our portfolio offered to property managers and house owners we focus on climate-friendly, safe and comfortable living environment. In our technology lab we offer digital solutions for our customers worldwide.

Sustainability

One of the greatest challenges of our time is the responsible and careful use of natural resources such as energy and water. We help our customers sustainably save energy, CO2 and costs in buildings with all our energy.

Источник

Распределитель затрат отопления допримо 3 радио счётчик распределитель тепловой энергии

Инновации в системах учёта тепла. Вот о чём пойдёт речь. Модель прибора учёта тепловой энергии, которую мы представляем называется Ista Doprimo 3 radio радио net art. 11490 heat cost allocator, heizkostenverteiler, repartiteur des frais de chauffage radiateur de couts, asignadores de costes radiador. Contabilizzatori di riscaldamento. Такой индивидуальный радиаторный тепловой счетчик распределитель имеет смысл устанавливать в квартиру в многоквартирном доме, с вертикальной разводкой. Устанавливать обычные приборы учета- квартирные, в таком случае не выгодно, т.к. придется устанавливать отдельный прибор на каждый подвод к радиатору, что, конечно, очень накладно. В этом случае можно применить, так называемые, радиаторные счётчики распределители тепла.

Для распределения расходов тепла между жильцами в ТСЖ и УК с централизованными системами отопления используются электронные распределители последнего поколения, предназначенные для распределение тепловой энергии и денежные затраты в квартирах. К вашим услугам счётчик пропорционатор . Распределение расходов на одну квартиру- дом производится с помощью
специализированной программы. Использование распределителей затрат на отопление представляется более дешевой альтернативой теплосчётчиков, установленных на подводе к каждому обогревательному прибору и смонтированному в трубопровод в виде расходомера и термостопротивления.
Описание
Ista Doprimo-это электронный распределитель затрат на отопление, который работает посредством разницы показаний датчиков температуры отопления на элементе обогрева (радиаторе), и температуре окружающей среды (комнатный датчик) . Датчик температуры окружающей среды позволяет учесть тепловую энергию только после определенной температуры, установленный порог превышен. Корпус устройства выполнен из пластика устойчивого к высоким температурам. Она содержит электронные дисплей- многофункциональный ЖК-экран, аккумулятор, и датчики температуры. Оптический порт предназначен для обмена с контроллером и монтируется на на передней стороне распределителя. Тепловой контакт с радиатором обеспечивается через тепловой адаптер из алюминия, на который монтируется счётчик распределитель тыльной стороной. Счётчик распределитель крепится на радиатор с помощью комплекта монтажных элементов, так чтобы был обеспечен хороший кон такт между ними. Распределитель тепловой энергии при монтаже пломбируется. Распределитель затрат тепла позволяет избежать ошибочных показаний расхода из-за случайного обогрева различной природы. Электронный распределитель может быть запрограммирован с помощью оптического датчика и персонального компьютера или с помощью переносного программатора через
оптический порт. Программируются следующие величины:
— серийный номер;
— M-bus адрес;
— пароль;
— K-коэффициент на вид прибора и размер;
— Дата и время

Преимущества ista doprimo 3 radio danfoss x-10v: indiv-10, он соответствует EN 834, 2-датчика температуры, Дистанционное обслуживание датчика (по запросу), Радио системы 868 МГц беспроводной M-BUS в соответствии с EN 13757-4, Этот стандартный протокол позволяет использовать несколько радиоприемных устройств, доступных на рынке, при условии, что они находятся в соответствии с действующими нормативами, Стационарные или переменной scale (большая библиотека поправочных коэффициентов К, Оптический интерфейс для настройки параметров и загрузки данных, AES-128 шифрования для безопасной передачи данных (включено), Защита от вскрытия и внешних источников тепла, можно включать и настраивать летний режим, 10 лет эксплуатации без обслуживания.

Распределитель энергетических ресурсов определяет, запоминает и отображает в единицах, необходимых для расчета ежемесячного расхода тепла, также запоминает данные о тепловой энергии потреблённой в течение предыдущих 24 месяцев. Эти записи могут быть прочитаны на ЖК- дисплее распределителя тепла, или они могут быть в электронном виде считаны через оптический порт.

Чем отличается тепловой счетчик от распределителя затрат на отопление допримо 3

Преимуществом прибора распределения затрат тепловой энергии является то, что крепление прибора на радиатор производится без вмешательства в систему отопления.

Распределитель тепла предназначен для измерения относительного количества тепловой энергии, отданной каждым радиатором в квартире. На основе показаний распределителей тепла и общедомового теплового счетчика расчитывается абсолютная доля затрат каждого владельца квартиры в доме. Самый простой способ- способ пропорции и выделения абсолютного значения доли.

Для расчетов обычно используют Методику Госстроя РФ (МДК 4–06.2004). Применение поквартирного учета тепла с использованием распределителей позволяет каждому жильцу регулировать поступление тепла в свою квартиру, а значит и экономить на отоплении. Экономия потребления тепла в домах, оснащенных распределителями, обычно снижается на 20-50%.

А теперь о том почему нельзя просто купить и поставить этот прибор?

На радиаторах отопления, оснащенных распределителями тепла должны быть обязательно установлены регуляторы температуры (известно, что данное требование исполненно не везде).

Распределителями тепла в здании должно быть оснащено не менее 50% отапливаемых помещений.

Процент диктуется методикой, утвержденной Госстроем. И обусловлена точностью полученных результатов.

МЕТОДИКА РАСПРЕДЕЛЕНИЯ ОБЩЕДОМОВОГО ПОТРЕБЛЕНИЯ тепловой. энергии НА ОСНОВЕ ПОКАЗАНИЙ КВАРТИРНЫХ ПРИБОРОВ УЧЕТА ТЕПЛОТЫ

МДК 4-07.2004, предлагается изучить проектировщикам раздела автоматика при использовании а качестве радиаторного распределителя Иста Допримо 3r альтернатива (замена) Danfoss X-10R паспорт к которому вы можете скачать на нашем сайте.

2.1. Методика рекомендована к применению на территории Российской Федерации в многоквартирных жилых зданиях, снабжаемых тепловой энергией от систем центрального отопления.

3.5. Квартирные приборы учета теплоты — это приборы для регистрации необходимых параметров теплопотребления в соответствии с п. 3.4. В качестве квартирных приборов учета, в зависимости от регистрируемого набора параметров, в настоящий момент допускается использование квартирных счетчиков теплоты или радиаторных устройств для распределения тепловой энергии (далее по тексту — распределителей теплоты).

4.7. В силу положений пп. 4.4 4.6 невозможно ставить вопрос о метрологически точном определении доли данного потребителя в общедомовом потреблении. Поэтому ключевым понятием при расчете поквартирных оплат за тепловую энергию является «зависящая от показаний квартирных приборов учета расчетная доля данного потребителя в общедомовом потреблении».

5.6. Распределители теплоты используют в качестве квартирных приборов учета в основном при вертикальной разводке системы отопления. Однако использование распределителей теплоты возможно также и при горизонтальной разводке. В любом случае распределителями теплоты должны быть оборудованы не менее 50 % помещений расчетной единицы, используемых индивидуальными потребителями

9.3. Далее из общего потребления следует вычесть оценочные величины потребления теплоты (по установленным нормам) в тех квартирах, в которых:

— не установлены квартирные приборы учета;

Доля таких квартир в расчете должна составлять не более 15—25 % с тем, чтобы обеспечить отклонение среднего расчетного потребления на 1 кв. м в остальных квартирах от среднего фактического потребления на 1 кв. м не более чем на 10—15 % (приложение №1). Наша модель- Ista Doprimo является полноправным аналогом INDIV-5-5R Счетчик- распределитель от Danfoss артикул: 088H2331P 088H2330P и старой модели indiv 3 088H2200 с визуальным считыванием.

Внимание. Реализация счётчиков-распределителей тепла производитс только через строительные и монтажные предприятия в количествах не менее 50-70% от всех радиаторов жилого дома, что соответствует рекомендациям завода изготовителя.

Находимся территориально близко к г. Костанай, г. Рудный, Казахстан.

Innovations in systems of heat. This is what will be discussed. Model metering of thermal energy, which we present is called Ista Doprimo 3r art. 11490. This individual radiator heat counter dispenser has the meaning set in an apartment in an apartment house, with a vertical layout. To install a conventional metering devices — flat, in this case, is not profitable, since it is necessary to install a separate device for each supply to the radiator, which, of course, very expensive. In this case, it is possible to apply the so-called radiator counters heat distributors.
For cost allocation of heat between residents in the HOA and management company with centralized heating systems use electronic distributors of the last generation, designed for the distribution of thermal energy and money in the apartments. It offers counter proportionator. The distribution of expenditures per apartment — house produced using
specialized programs. The use of distributors of heating costs seems to be a cheaper alternative heat meters installed on the cart to each of the heating device and mounted in the pipeline in the form of a flow meter and thermocapillary.
Description
Ista Doprimo is an electronic measurement distributor that runs through the difference in the readings of the temperature sensors heating element heating (radiator), and the ambient temperature (room sensor). Sensor ambient temperature allows to take into account the thermal energy only after a certain temperature, the preset threshold is exceeded. The housing is made of plastic resistant to high temperatures. It contains electronic display — multi-function LCD screen, battery, and temperature sensors. Optical port for
exchange with the controller and mounted on the front side of the distributor. Thermal contact with a heat sink is provided through the heat adapter made of aluminum, on which is mounted a counter dispenser back. Counter dispenser is mounted on the heat sink by using a set of Assembly elements to ensure good contact between them. Allocator of thermal energy when the Assembly is sealed. The heating measurement cost of heat allows you to avoid erroneous indications of flow rate due to accidental heating of different nature. Electronic dispenser can be programmed using an optical sensor and a personal computer or by using a portable programmer through
optical port. Programmed with the following values:
— the serial number;
— M-bus address;
— password;
— K-factor on the type of device and size;
— Date and time
Advantages: Meets EN 834, 2-temperature sensor Remote room sensor (on request), Radio system 868 MHz wireless M-BUS according to EN 13757-4, This standard Protocol allows multiple receivers available on the market, provided that they are in compliance with existing regulations, Fixed or variable scale (large library of correction coefficient K, the Optical interface to configure settings, and load data, AES-128 encryption for secure data transfer (included), opening Protection, and external heat sources, you can enable and configure summer mode, 10 years of maintenance-free service.

Distributor of energy resources determines, records and displays in units necessary to calculate the monthly heat consumption, also stores data of thermal energy consumed during the previous 24 months. These records can be read on the LCD display heat distributors, or they can be electronically read out via the optical port.
What distinguishes the heat meter heat from the distributor

The advantage of the device cost distribution of thermal energy is that the mounting device on the heat sink is made without interfering with the heating system.

The heat distributor is designed to measure the relative amount of thermal energy given to each radiator in the apartment. On the basis of the evidence distributors of heat and household energy meter calculates the absolute share of the cost of each apartment owner in the house. The easiest way is the way of the aspect ratio and the allocation of the absolute value of the shares.

For calculations typically use the Technique of Gosstroy of the Russian Federation (MDK 4-06 .2004). The use of individual heat metering using distributors allows each tenant to regulate the flow of heat in my apartment, and thus to save on heating. Savings in heat consumption in houses with distributors, is usually reduced by 20-50%.

And now about why you can’t just buy and put this device?

On the radiators with valves heat must be set to temperature controllers (it is known that this requirement is completed, not everywhere).

Distributors of heat in the building must be equipped with at least 75% of the heated space.

The percentage is dictated by the methodology approved by the construction Committee. And due to the accuracy of the results.

THE METHOD OF DISTRIBUTION OF HOUSEHOLD CONSUMPTION OF THERMAL

ENERGY FOR HEATING BETWEEN INDIVIDUAL CONSUMERS

ON THE BASIS OF THE EVIDENCE OF RESIDENTIAL METERING OF HEAT

2.1. This method is recommended for use on the territory of the Russian Federation in the apartment buildings supplied with thermal energy from Central heating systems.

3.5. Residential metering of heat is devices for the recording of the required parameters of heat consumption in accordance with p. 3.4. As a home of meters, depending on register settings, currently allowed for use of room counters of heat or radiator devices for distribution of thermal energy (hereinafter distribution of heat).

4.7. Pursuant to the provisions of paras. 4.4 4.6 impossible to raise the issue of metrologically accurate determination of the share of the consumer in household consumption. Therefore, a key concept when calculating quarterly payments for the thermal energy is dependent on the testimony of residential metering the estimated share of the consumer in household consumption».

5.6. Distributors of heat is used as the housing of the metering devices mainly in the vertical distribution of the heating system. However, the use of distributors warmth is also possible for horizontal wiring. In any case, the distributors of heat must be equipped with at least 75 % of the premises of the unit of account used by individual consumers

9.3. Further, of the total consumption should be subtracted estimates of consumption of heat (by the established norms) in those homes in which:

— not established residential metering devices;

The share of such apartments in the calculation should be no more than 15-25 % in order to ensure that the deviation of estimated consumption per 1 sq. m in the rest of the apartments from the average actual consumption per 1 square meter no more than 10-15 % (Annex 1). Our model — Ista Doprimo is a full analogue of INDIV-5-5R heat cost allocator from Danfoss code: 088H2331P 088H2330P and old model indiv 3 088H2200 with visual reading.

Are geographically close to, Kostanai, Rudny, Kazakhstan.

La innovación en los sistemas de contabilidad de calor. Y de eso es de lo que se pretende. El modelo de la unidad de contabilidad de la energía térmica, que presentamos se llama Ista Doprimo 3r art. 11490. Tal individual радиаторный medidor de calor distribuidor tiene sentido instalarse en un apartamento en un edificio de apartamentos, con cableado vertical. Instalar los dispositivos ordinarios de contabilidad de habitacin, en este caso, no es beneficioso, ya que es necesario instalar un accesorio por separado en cada uno de refrigerante hacia el radiador, que, por supuesto, muy caro. En este caso, se pueden aplicar, los llamados, los radiadores, los contadores de los distribuidores de calor.
Para la distribución de los gastos de calor entre los residentes en la asociación de propietarios y el código penal centralizados de calefacción se utilizan dispensadores electrónicos de última generación, diseñados para la distribución de la energía térmica y los costos en los apartamentos. Dispone de un contador de пропорционатор. La asignación de costos en un apartamento — casa se realiza mediante una
un programa especializado. El uso de los distribuidores de costes de calefacción, parece la alternativa más barata теплосчетчиков instalados en el abastecimiento a cada обогревательному dispositivo y смонтированному en la tubería en forma de impulsos y термостопротивления.
Descripción
Ista Doprimo es un distribuidor, que funciona a través de la diferencia de las lecturas del sensor de temperatura de la calefacción en el elemento de calefacción (radiador), y la temperatura ambiente (sala de sensor). El sensor de la temperatura ambiente para tener en cuenta la energía térmica que sólo después de una cierta temperatura de umbral es excedido. La carcasa está hecha de plástico resistente a altas temperaturas. Contiene la electrónica y una pantalla multifunción con pantalla LCD, batería, y los sensores de temperatura. Puerto óptico está diseñado para
el intercambio con el controlador y se monta en la parte frontal del dispensador. Térmica de contacto con el disipador de calor se proporciona a través del calor con el adaptador de aluminio, en el que se monta el contador de el distribuidor con la parte trasera. Contador de distribuidor se fija en el disipador de calor con el kit de montaje de los elementos, de manera que se logre un buen contacto entre ellos. El distribuidor de la energía térmica durante el montaje пломбируется. Dispensador de costes de calor permite evitar errónea de caudal debido accidentalmente a la calefacción de distinta naturaleza. Electrónico de dispensador puede ser programado mediante un sensor óptico y una computadora personal o con la ayuda de un programador a través de
puerto óptico. Se programan las siguientes magnitudes:
— número de serie;
— M-bus de dirección;
— la contraseña;
— K es el factor en el tipo de aparato y el tamaño;
— La fecha y la hora
Ventajas: Cumple la norma EN 834, 2-sensor de temperatura del mantenimiento a distancia del sensor (bajo petición), La radio del sistema 868 Mhz wireless M-BUS, de acuerdo con en 13757-4, Este protocolo estándar que permite utilizar varios радиоприемных de los dispositivos disponibles en el mercado, siempre que estén en conformidad con las normas vigentes, Fijo o variable scale (la gran biblioteca de los coeficientes de corrección de La Óptica de la interfaz para configuración y descarga de datos, AES-128 de cifrado para la transmisión segura de datos (incluido), la Protección de la autopsia y de las fuentes externas de calor, puede activar y configurar años de edad, el modo de 10 años de funcionamiento sin necesidad de mantenimiento.

El distribuidor de los recursos energéticos determina, recuerda y muestra, en unidades necesarias para el cálculo mensual de consumo de calor, también recuerda los datos sobre la energía térmica consumida en los últimos 24 meses. Estos registros pueden ser leídos en la pantalla LCD del distribuidor de calor, o pueden ser en forma electrónica a leer a través del puerto óptico.
Que se distingue del medidor de calor del distribuidor de calor

La ventaja de la unidad de distribución de costes de la energía térmica es el hecho de que la fijación del aparato en el disipador de calor se realiza sin intervención en el sistema de calefacción.

Dispensador de calor está diseñado para la medición de la cantidad relativa de energía térmica entregada a cada radiador en el apartamento. En la base de las declaraciones de los distribuidores de calor y общедомового de calor contador absoluta se calcula la proporción de los gastos de cada propietario de un apartamento en la casa. El método más sencillo es el método de las proporciones y de la selección absoluta de proporción.

Para los cálculos normalmente utilizan la Metodología del rgimen estatal de la FEDERACIN rusa (MDK 4-06 .2004). La aplicación de поквартирного recuento de calor con el uso de la válvula permite que cada inquilino de regular la entrada de calor en su apartamento y, así, ahorrar en calefacción. Ahorro de consumo de calor en los hogares equipados con распределителями, normalmente se reduce en un 20%al 50%.

Y ahora por qué no se puede simplemente comprar y poner este aparato?

En los radiadores de calefacción equipados con распределителями de calor debe ser siempre instalados los reguladores de la temperatura (se sabe que este requisito исполненно no en todas partes).

Распределителями de calor en el edificio debe estar dotado de al menos el 75% de las instalaciones.

El porcentaje de dictada la metodología aprobada por el rgimen estatal. Y está condicionada a la precisión de los resultados obtenidos.

LA METODOLOGÍA DE ASIGNACIÓN ОБЩЕДОМОВОГО CONSUMO DE CALOR

DE ENERGÍA PARA LA CALEFACCIÓN ENTRE LOS CONSUMIDORES INDIVIDUALES

SOBRE LA BASE DE LECTURAS DE LOS MEDIDORES DE CALOR

2.1. La metodología recomendada para la aplicación en el territorio de La Federación de rusia en bloques de edificios de apartamentos que disponen la energía térmica de los sistemas de calefacción central.

3.5. Habitacin los medidores de calor son aparatos para el registro de los parámetros necesarios теплопотребления de conformidad con el apartado 3.4. Como los instrumentos de contabilidad, en función de facturado el conjunto de parámetros, en este momento se permite el uso de los contadores de calor o радиаторных de dispositivos para la distribución de energía térmica (en adelante, los distribuidores de calor).

4.7. En virtud de las disposiciones del pp. 4.4 4.6 no se puede plantear la cuestión de метрологически determinar con precisión el porcentaje del consumidor en общедомовом consumo. Por lo tanto, es un concepto clave al calcular поквартирных de los pagos por la energía térmica es «dependiendo de las lecturas de los medidores y la proporción estimada del consumidor en общедомовом el consumo».

5.6. Distribuidores de calor se utilizan como los medidores y en general a la vertical de las clavijas de la conexión del sistema de calefacción. Sin embargo, el uso de los distribuidores de calor también es posible y horizontal de las clavijas de la conexión. En cualquier caso, распределителями de calor deben estar equipadas con al menos el 75 % de los hogares como unidad de cuenta, utilizados por los consumidores individuales

9.3. Siguiente de consumo total debe restar las estimaciones de la magnitud del consumo de calor (por las normas establecidas en los apartamentos, en los que:

— no se instalarán aparatos de habitacin de contabilidad;

La proporción de estos apartamentos en el cálculo debe ser de no más de 15 % a 25% con el fin de garantizar la desviación de la media de facturación de consumo en 1 metros cuadrados en el resto de departamentos de la media del consumo real por 1 sq. m. no más de un 10-15 % (anexo nº 1). Nuestro modelo — Ista Doprimo es un análogo de INDIV-5-5R de la Contador — distribuidor de Danfoss artículo número: 088H2331P 088H2330P y el viejo modelo indiv 3 088H2200 con imágenes de la lectura.

Estamos geográficamente cerca, Костанай, Рудный, Kazajstán.

Innovation in den Systemen für Wärme. Das ist, worum es sich handelt. Modell des Gerätes für die Wärme, die wir genannt Ista Doprimo 3r art. 11490. So eine individuelle радиаторный Wärmezähler Zufuhr sinnvoll zu installieren, in eine Wohnung in einem Mehrfamilienhaus, mit senkrechten Abzweig. Installieren herkömmliche Messgeräte — Wohnung, in einem solchen Fall nicht von Vorteil, da muss eine separate Befestigung auf jeden Zuleitung an den Heizkörper, was natürlich sehr teuer. In diesem Fall können Sie anwenden, so genannte Kühler Zähler Verteiler Wärme.
Für die Verteilung der Kosten der Wärme zwischen den Bewohnern der TSG und des Strafgesetzbuches mit zentralen Heizsystemen verwendet elektronische Verteiler der neuesten Generation, speziell für die Verteilung der Wärmeenergie und die Cash-Kosten in den Wohnungen. Freuen Sie sich auf einen Zähler пропорционатор. Die Verteilung der Kosten auf eine Wohnung — das Haus wird mit Hilfe der
ein spezielles Programm. Die Verwendung der Ventile Kosten für Heizung scheint eine billigere Alternative Wärmezähler, die auf der Zufuhr zu jedem обогревательному Gerät und смонтированному in der Pipeline als Durchflussmesser und термостопротивления.
Beschreibung
Ista Doprimo ist ein E-Wegeventil, das funktioniert, indem die Differenz der Messwerte der sensoren, die Temperatur der Heizung auf ein Element in der Heizung (Heizkörper)und Umgebungstemperatur (innen-Sensor). Der Sensor der Temperatur der Umwelt ermöglicht die Berücksichtigung thermische Energie nur nach einer bestimmten Temperatur, der eingestellte Grenzwert überschritten wird. Das Gehäuse besteht aus Kunststoff nachhaltige gegenüber hohen Temperaturen. Es enthält eine elektronische Anzeige — Multifunktions-LCD-Display, Batterie-und Temperatur-sensoren. Optischer Anschluss ist für
Austausch mit Controller und montiert auf der Vorderseite des Verteilers. Thermischen Kontakt mit dem Kühler durch thermische Adapter aus Aluminium, auf dem er montiert Zähler Verteiler der Rückseite. Zähler Verteiler montiert auf Kühlkörper mit Hilfe des Montage-Elemente, so dass gewährleistet war ein guter Kontakt zwischen den beiden. Zufuhr von thermischer Energie bei der Montage versiegelt ist. Der Verteiler Kosten Wärme vermeidet fehlerhafte Messwerte Durchfluss aufgrund der zufälligen Beheizung von unterschiedlicher Natur. Elektronische Verteiler kann so programmiert werden, mit Hilfe eines optischen Sensor und PC oder mithilfe eines tragbaren Handsteuerung durch
LWL-Port. Programmiert werden die folgenden Größen:
— Seriennummer;
— M-bus-Adresse;
— Passwort;
— K-Verhältnis auf eine Art von Gerät und Größe;
— Datum und Uhrzeit
Vorteile: Erfüllt die EN 834, 2-Temperatur-Sensor, Remote-Service-Sensor (auf Anfrage), Radio-System 868 MHz-Wireless-M-BUS nach EN 13757-4, Das Standard-Protokoll ermöglicht es, mehrere Radio-Empfangs-Geräte auf dem Markt, vorausgesetzt, dass Sie in übereinstimmung mit den bestehenden Vorschriften, Feste oder Variable scale (die große Bibliothek von Korrekturfaktoren Zu, Optische Schnittstelle zur Konfiguration der Einstellungen und Daten zu laden, AES-128-Verschlüsselung für die sichere übertragung der Daten (aktiviert), der den Schutz der Autopsie und externen Wärmequelle, können Sie aktivieren und konfigurieren Sommerbetrieb, 10 Jahre Betrieb ohne Service.

Zufuhr der Energie-Ressourcen ermittelt, speichert und zeigt in Einheiten, die für die Berechnung der monatlichen Wärmefluss, erinnert sich auch an, die Daten über die thermische Energie verbraucht innerhalb der letzten 24 Monate. Diese Einträge gelesen werden kann auf dem LCD — Display des Verteilers Wärme, oder Sie können in elektronischer Form gelesen über den optischen Ausgang.
Was unterscheidet die Wärmezähler vom Verteiler Wärme

Der Vorteil des Gerätes auf die Verteilung der Kosten der Wärmeenergie ist, dass die Befestigung des Gerätes an der Heizkörper erfolgt ohne Eingriff in die Heizungsanlage.

Zufuhr von Wärme ist für die Messung der relativen Menge an Wärmeenergie, der gespendeten einzelnen Heizkörper in der Wohnung. Auf der Grundlage der Aussagen der Ventile Wärme und общедомового thermischen Zähler wird der absolute Anteil der Kosten der einzelnen Eigentümer einer Wohnung in einem Haus. Der einfachste Weg — ein Weg, die Proportionen und die Zuweisung der absolute Wert der Anteile.

Für die Berechnungen verwenden in der Regel die Methodik der Russischen Föderation (MDK 4-06 .2004). Anwendung поквартирного Berücksichtigung der Wärme mit Ventilsystem ermöglicht es jedem Mieter zu regulieren der Wärmeeintrag in seine Wohnung, und somit zu sparen und die heizkosten. Die Einsparung des Verbrauchs von Wärme in den Häusern, die mit Wegeventilen, sinkt im Allgemeinen 20 und 50%.

Und nun, warum kann man nicht einfach kaufen, und setzen Sie dieses Gerät?

Auf den Kühler Heizung, mit Wegeventilen Wärme sollte unbedingt installiert Temperaturregler (es ist bekannt, dass diese Forderung исполненно nicht überall).

Wegeventilen Wärme in das Gebäude muss über nicht weniger als 75% der beheizten Räumen.

Der Prozentsatz der durch die Methodik, genehmigt von der Staatsordnung. Und aufgrund der Genauigkeit der Ergebnisse.

DIE METHODIK DER VERTEILUNG DES KONSUMS DER THERMISCHEN ОБЩЕДОМОВОГО

ENERGIEVERBRAUCH FÜR DIE HEIZUNG ZWISCHEN DEN EINZELNEN VERBRAUCHER

BASIEREND AUF DEN AUSSAGEN VON WOHN-MESSGERÄTE WÄRME

Ein kurzer Auszug:

2.1. Die Methodik empfohlen zur Anwendung auf dem Territorium der Russischen Föderation in Mehrfamilien-Wohngebäude, снабжаемых thermische Energie von Heizungsanlagen.

3.5. Wohnungs-Messgeräte für Wärme — es Geräte, die für die Registrierung erforderlichen Parameter des Wärmeverbrauchs in übereinstimmung mit Absatz 3.4. Als Wohn-Messgeräte, die in Abhängigkeit vom angemeldeten Reihe von Parametern, im Moment ist zulässig Wohn-Zähler Wärme oder радиаторных Geräte für die Verteilung thermischer Energie (weiter im Text — Ventile Wärme).

4.7. Aufgrund der Bestimmungen des ABS. 4.4 4.6 unmöglich, die Frage zu stellen, über den eichamtlich genaue Ermittlung des Anteils des Verbraucher in общедомовом Verbrauch. Daher ist der Schlüssel bei der Berechnung der поквартирных Gebühren für die thermische Energie ist «abhängig von der Indikation Wohn-Messgeräte der geschätzte Anteil des Verbraucher in общедомовом Konsum».

5.6. Verteiler Wärme wird als Wohn-Messgeräte vor allem bei der senkrechten Abzweig der Heizungsanlage. Jedoch ist die Verwendung von Ventilen Wärme möglich, auch bei horizontalem Layout. In jedem Fall Wegeventilen Wärme werden müssen, sind mit nicht weniger als 75 % der Räume der Rechnungseinheit, der verwendeten einzelnen Verbraucher

9.3. Weiter aus der gemeinsamen Einnahme sollten abziehen Schätzungen der Größenordnung des Verbrauchs von Wärme (nach der geltenden Norm) in den Wohnungen, in denen:

— nicht installiert Wohnungs-Messgeräte;

Der Anteil solcher Wohnungen in der Berechnung beträgt 15-25%, um die Abweichung der mittlere geschätzte Verbrauch auf 1 qm in den übrigen Wohnungen von der durchschnittlichen tatsächlichen Verbrauch auf 1 Quadratmeter nicht mehr als 10-15 % (Anlage 1). Unser Modell — Ista Doprimo ist ein vollwertiges Analog INDIV-5-5R Counter — Verteilung von Danfoss Artikelnummer: 088H2331P 088H2330P und alten Modell indiv 3 088H2200 mit der visuellen Auslesen.

Sind geographisch nah an das Jahr Kostanay, Erz, Kasachstan.

Інавацыі ў сістэмах уліку цяпла. Вось аб чым пойдзе гаворка. Мадэль прыбора ўліку цеплавой энергіі, якую мы ўяўляем называецца Ista Doprimo 3r art. 11490. Такі індывідуальны радыятарны цеплавой лічыльнік размеркавальнік мае сэнс ўсталеўваць у кватэру ў шматкватэрным доме, з вертыкальнай разводкай. Ўсталеўваць звычайныя прыборы ўліку — кватэрныя, у такім выпадку не выгадна, бо прыйдзецца ўсталеўваць асобны прыбор на кожны фурманак да радыятары, што, вядома, вельмі накладна. У гэтым выпадку можна ўжыць, так званыя, радиаторные лічыльнікі размеркавальнікі цяпла.
Для размеркавання выдаткаў цяпла паміж жыхарамі ў ТСЖ і КК з цэнтралізаванымі сістэмамі ацяплення выкарыстоўваюцца электронныя размеркавальнікі апошняга пакалення, прызначаныя для размеркаванне цеплавой энергіі і грашовыя выдаткі ў кватэрах. Да вашым паслугах лічыльнік пропорционатор. Размеркаванне выдаткаў на адну кватэру — дом вырабляецца з дапамогай
спецыялізаванай праграмы. Выкарыстанне размеркавальнікаў выдаткаў на ацяпленне падаецца больш таннай альтэрнатывай теплосчетчиков, устаноўленых на подводе да кожнага обогревательному прыбору і смонтированному ў трубаправод у выглядзе расходомера і термостопротивления.
Апісанне
Ista Doprimo-гэта электронны размеркавальнік, які працуе з дапамогай розніцы паказанняў датчыкаў тэмпературы ацяплення на элеменце абагравання (радиаторе), і тэмпературы навакольнага асяроддзя (пакаевы датчык). Датчык тэмпературы навакольнага асяроддзя дазваляе ўлічыць цеплавую энергію толькі пасля пэўнай тэмпературы, устаноўлены парог не перавышаны. Корпус прылады выкананы з пластыка ўстойлівага да высокім тэмпературам. Яна змяшчае электронныя дысплей — шматфункцыянальны ВК-экран, акумулятар, і датчыкі тэмпературы. Аптычны порт прызначаны для
абмену з кантролерам і мантуецца на на пярэдняй баку размеркавальніка. Цеплавы кантакт з радыятарам забяспечваецца праз цеплавой адаптар з алюмінія, на які мантуецца лічыльнік размеркавальнік тыльным бокам. Лічыльнік размеркавальнік мацуецца на радыятар з дапамогай камплекта мантажных элементаў, так, каб быў забяспечаны добры кантакт паміж імі. Разьмеркавальнік цеплавой энергіі пры мантажы пломбируется. Разьмеркавальнік выдаткаў цяпла дазваляе пазбегнуць памылковых паказанняў выдатку з-за выпадковага абагравання рознай прыроды. Электронны размеркавальнік можа быць запраграмаваны з дапамогай аптычнага датчыка і персанальнага кампутара або з дапамогай пераноснай программатор праз
аптычны порт. Праграмуюцца наступныя велічыні:
— серыйны нумар;
— M-bus адрас;
— пароль;
— K-каэфіцыент на выгляд прыбора і памер;
— Дата і час
Перавагі: Адпавядае EN 834, 2-датчыка тэмпературы, Дыстанцыйнае абслугоўванне датчыка (па запыце), Радые сістэмы 868 МГц бесправадной M-BUS ў адпаведнасці з EN 13757-4, Гэты стандартны пратакол дазваляе выкарыстоўваць некалькі радиоприемных прылад, даступных на рынку, пры ўмове, што яны знаходзяцца ў адпаведнасці з дзеючымі нарматывамі, Стацыянарныя або зменнай scale (вялікая бібліятэка поправочных каэфіцыентаў Да, Аптычны інтэрфейс для налады параметраў і загрузкі дадзеных, AES-128 шыфравання для бяспечнай перадачы дадзеных (уключана), Абарона ад выкрыцця і знешніх крыніц цяпла, можна ўключаць і наладжваць летні рэжым, 10 гадоў эксплуатацыі без абслугоўвання.

Разьмеркавальнік энергетычных рэсурсаў вызначае, запамінае і адлюстроўвае ў адзінках, неабходных для разліку штомесячнага расходу цяпла, таксама запамінае дадзеныя аб спажытай цеплавой энергіі на працягу папярэдніх 24 месяцаў. Гэтыя запісы могуць быць прачытаны на ВК — дысплеі размеркавальніка цяпла, або яны могуць быць у электронным выглядзе прачытаныя праз аптычны порт.
Чым адрозніваецца цеплавой лічыльнік ад&l

Источник