- Кабель для подключения консоли циско
- Схема подключения и оборудование Cisco
- Настройки COM-порта
- Команды в терминале Cisco
- Подключение к оборудованию Cisco
- 1) Настройка с помощью консольного кабеля
- 2) Настройка с помощью Rollover кабеля через другой маршрутизатор
- 3) Удаленный доступ
- Кабель интерфейсный Cisco CAB-CONSOLE-USB
- Основные характеристики
- Требуется коммерческое предложение?
- Cabling Guide for Console and AUX Ports
- Available Languages
- Download Options
- Contents
- Introduction
- Prerequisites
- Requirements
- Components Used
- Conventions
- Table of Routers with Console and AUX Ports
- Console Port Settings for Terminal Connection
- Types of Console and AUX Connectors
- Types of RJ-45 Cabling
- How to Identify an RJ-45 Cable
- Straight-through Cable
- Crossover Cable
- Rolled Cable
- RJ-45 to DB-9 Female*
- Type of Cable for DB-25 Connectors
- Adapters
- RJ-45-to-DB-9 Adapter
- RJ-45-to-DB-25 Adapter
- Cabling and Adapter Setups that Work
- RJ-45 Port and Adapter Pin-outs
- DB-25 Console and AUX Port Pin-outs
- Console Cable Kit
- Cisco RJ-45 Component Guide
Кабель для подключения консоли циско
Всем привет сегодня хочу освежить в памяти как производится начальная настройка cisco через COM-порт. Когда вы получаете новое оборудование, оно как правило имеет заводские настройки, которые врят ли кому подходят, в том числе и Cisco. Единственным способом осуществить первоначальную настройку, хотя бы назначить ip адрес и включить ssh для удаленного доступа, является подключение через COM-порт, в комплекте всегда идет специальный голубой провод.
Схема подключения и оборудование Cisco
И так базовая настройка cisco начинается, вот как выглядит схема подключения COM-портом к нашему сетевому оборудованию.
С одной стороны на сетевом оборудовании есть консольный порт вида мини USB либо формата RJ45.
Вот как выглядят фирменные провода для подключения через console port cisco. Кстати новый оригинальный голубой провод стоит 15 баксов.
Если у вас например ноутбук или стационарный компьютер не имеют разъема на материнской плате для COM-порт, то есть переходники COM-порт to USB.
Настройки COM-порта
Настройки COM-порта для подключения к Cisco можете посмотреть по данной ссылке, я ранее делал себе заметку из них самое главное это:
- Speed > скорость передачи данных в секунду
- Data bits
- Stop bits
Подключаться я буду через терминал в Cisco packet tracer 6.4, но и покажу как это происходит и через всем известную putty.
В putty базовая настройка cisco, начинается с вкладки Serial, тут нужно убедиться, что все настройки выставлены как я показывал вам выше.
Далее идем на вкладку Session и выбирем Serial, в поле Serial Line укажите нужный Com port.
Если не знаете какой у вас Com порт используется, то делаете следующее, нажимаете Win+R и вводите devmgmt.msc, у вас откроется диспетчер устройств.
И в пункте Порты (COM и LPT) смотрим ваши номера.
Вы попадаете в терминальную сессию, первым делом нужно удалить стартовый конфиг, делается это просто:
Все теперь ваше устройство не содержит ни каких настроек и при первой загрузке вы получаете стандартный мастер настройки System Configuration Dialog, я если честно всегда говорю нет и привык делать все в ручную, на мой взгляд это нужно уметь делать, если вам вдруг нужно вызвать меню мастера первоначальных настроек, то это делается командой setup.
Команды в терминале Cisco
Настройка cisco осуществляется с помощью списка команд, посмотреть который можно введя ?
Такое малое количество команд означает,ч то мы находимся в обычном режиме терминала, попасть в привилегированный режим вводим
как видите, список команд существенно увеличился.
Зададим время clock set 13:53:00 28 nov 2016, у вас конечно оно будет своим, более детально как делается настройка времени cisco читайте по ссылке. Зададим dns имя вашему устройству, для этого заходим в режим настройки:
hostname и пишите нужное вам имя
и зададим домен ip domain-name и нужное имя домена
Следующим шагом нужно установить пароль на привилегированный режим в Cisco, а так же создать нового пользователя с возможностью логиниться из локальной базы. Далее настраиваем статический IP адрес и ssh или telnet доступ. После чего можно открывать у себя Putty и спокойно цепляться по удаленке, чтобы продолжить настройку Cisco так как вам это нужно. Надеюсь вы не уснули)))
Источник
Подключение к оборудованию Cisco
Read the article CONNECTING TO CISCO DEVICES in English
Для того, чтобы приступить к настройке оборудования Cisco, в первую очередь необходимо подключиться к консоли управления устройством. Рассмотрим случай, когда есть возможность осуществлять настройку с рабочей станции администратора в непосредственной близости от оборудования, а также имеется консольный или rollover кабель.
1) Настройка с помощью консольного кабеля
Настройка оборудования Cisco осуществляется с помощью консольного кабеля голубого цвета, который присутствует в комплекте с каждым устройством. Следует соединить COM порт рабочей станции администратора c консольным интерфейсом на устройстве Cisco (на нем будет написано CONSOLE или CON).
На современных персональных компьютерах и ноутбуках COM порт часто отсутствует. В этом случае можно приобрести переходник USB – COM (RS 232).
Для настройки я советую использовать простую и бесплатную программу Putty (Скачать с официального сайта)
После скачивания просто запустите ее и переставьте точку с «SSH» на «Serial» (как на картинке ниже), после чего нажмите кнопку «Open».
Важно!
Если вы используете переходник USB-COM, то номер порта может отличаться от 1. Проверить это можно в «диспетчере устройств» Windows в разделе Порты (COM и LPT). Если номер порта будет отличаться (Например COM7), то поменяйте значение COM1 на COM7 или иное.
Если вы подключили консольный кабель и питание устройства включено, то после нажатия кнопки «Open» должна открыться консоль управления. Если окно пустое, нажмите клавишу «Enter». Устройство должно выдать приветственную надпись, запрос логина и пароля или сразу же открыть консоль управления.
Router>
2) Настройка с помощью Rollover кабеля через другой маршрутизатор
В некоторых случаях получить доступ на оборудование можно, используя другой маршрутизатор Cisco, к которому уже есть доступ и специальный rollover кабель. Для понимания буду называть новым тот маршрутизатор, к которому нужно получить доступ, а старым тот, к которому уже организовано подключение (например удаленно через Telnet или SSH).
Rollover кабель не поставляется вместе с оборудованием Cisco, но его просто сделать своими руками из обычного патч корда, обрезав любой из наконечников и «переобжав» его клещами в той же последовательности проводов, но с перевернутым коннектором RJ 45.
Чтобы было понятно, что значит «с перевернутым коннектором», прилагаю схему:
Важно!
Последовательность проводов должна быть зеркальной.
Для подключения к консоли нового маршрутизатора необходимо соединить этим проводом AUX порт (черного цвета) старого маршрутизатора, к которому есть доступ, с CONSOLE портом (голубого цвета) нового маршрутизатора.
На старом маршрутизаторе, к которому есть доступ, из привилегированного режима (Знак # после имени устройства. Подробнее о режимах конфигурирования читайте в этой статье) необходимо добавить строки
R-DELTACONFIG# conf t
line aux 0
modem InOut
no exec
transport input all
stopbits 1
flowcontrol hardware
exit
После этого ввести команду
telnet х.х.х.х 2001
Где х.х.х.х – адрес любого собственного интерфейса старого маршрутизатора
Например, у маршрутизатора есть интерфейс с адресом 192.168.1.1. Тогда доступ к консоли соседнего маршрутизатора можно получить, введя команду
telnet 192.168.1.1 2001
Далее могут быть запрошены пароли
- к старому маршрутизатору, с которого осуществляется вход (пароль к самому себе, если установлен)
- к новому маршрутизатору, к которому осуществляется доступ (опять же, если есть)
После ввода пароля вы попадете в консоль управления новым маршрутизатором и можете приступать к его настройке.
3) Удаленный доступ
Удобнее всего настраивать оборудование все-таки удаленно, сидя в кресле за своим рабочим местом. О том, как это сделать быстро и безопасно читайте в статье «Доступ по протоколу SSH на Cisco«.
Источник
Кабель интерфейсный Cisco CAB-CONSOLE-USB
Доступно к заказу
Основные характеристики
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Отгрузка физическим лицам, в случае оплаты заказа банковскими картами, возможна только при предъявлении паспорта плательщика.
Для получения заказа, оплаченного вышеуказанным способом, третьим лицом необходимо наличие нотариально заверенной доверенности.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек. Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Мы предоставляем официальную гарантию на всю продукцию.
Сервис расширенной гарантии включает в себя:
- Приемку в сервисном центра для выполнения диагностики дефекта.
- Ремонт.
- Бесплатную доставку клиенту.
В рамках дополнительной программы оборудование Cisco Systems может быть поставлено с расширенной гарантией Cisco. Cрок расширенной гарантии Cisco – 12 месяцев с даты регистрации партнером продажи данного оборудования в базе данных компании Cisco Systems. По желанию клиента расширенная гарантия может быть продлена на следующие 12 месяцев по истечению первоначального срока или приобретена сразу на 24 или 36 месяцев.
Контакты гарантийного отдела:
Оставьте заявку в один клик и наш специалист свяжется с вами в кратчайшие сроки:
- Окажет профессиональную консультацию.
- Сообщит цену.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможное время доставки.
Связаться с отделом продаж Телефон:+7 495 003-13-35
E-mail:sale@ru-cisco.com
Требуется коммерческое предложение?
Для получения всей информации по вопросам комплектации, цен и наличия оборудования Cisco обратитесь в наш круглосуточный контакт-центр:
Источник
Cabling Guide for Console and AUX Ports
Available Languages
Download Options
Contents
Introduction
This document summarizes the cabling requirements for console and auxiliary (AUX) ports. Cisco routers either have RJ-45-based or DB-25 DCE/DTE console and AUX ports. You can connect either a terminal (DTE) or a modem (DCE) to these ports. In either instance, you need both an RJ-45 cable and an RJ-45-to-DB-25 or RJ-45-to-DB-9 connector.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Table of Routers with Console and AUX Ports
The table in this section lists the Cisco router series and the corresponding console and AUX ports.
Router | Console Port | Console Port Cable | AUX Port | AUX Port Cable |
---|---|---|---|---|
600 | RJ-45 (management port) | RJ-45 Rolled / RJ-45 to DB-9 Female | N/A | N/A |
700 | RJ-45 | RJ-45 Rolled | N/A | N/A |
800 | RJ-45 | RJ-45 Rolled / RJ-45 to DB-9 Female | N/A | N/A |
1000 | RJ-45 | RJ-45 Rolled | N/A | N/A |
1600 | RJ-45 | RJ-45 Rolled / RJ-45 to DB-9 Female | N/A | N/A |
1700 | RJ-45 | RJ-45 Rolled / RJ-45 to DB-9 Female | RJ-45 | RJ-45 Rolled |
2500 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
2600 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
3600 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
MC3810 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
4000 | DB-25 DCE | RS 232 / RJ-45 Rolled | DB-25 DTE | RS 232 / RJ-45 Rolled |
AS5200/5300 | RJ45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
AS5400 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
AS5800 | DB-25 DCE | RS 232 / RJ-45 Rolled | DB-25 DTE | RS 232 / RJ-45 Rolled |
7100/7200/7300 | RJ-45 | RJ-45 Rolled | RJ-45 | RJ-45 Rolled |
7200 | DB-25 DCE | RS 232 / RJ-45 Rolled | DB-25 DTE | RS 232 / RJ-45 Rolled |
7500 | DB-25 DCE | RS 232 / RJ-45 Rolled | DB-25 DTE | RS 232 / RJ-45 Rolled |
12000 | DB-25 DCE | RS 232 / RJ-45 Rolled | DB-25 DTE | RS 232 / RJ-45 Rolled |
Console Port Settings for Terminal Connection
Before you connect a terminal to the console port, configure the terminal to match the router console port as shown here:
2 stop bits (9600 8N2) OR 1 stop bit�
�Dependant on the router.
Types of Console and AUX Connectors
Cisco routers have three types of console and AUX connectors. The table in this section lists these types:
There are three styles of RJ-45-to-DB-25 connectors:
DCE style (modem)
DCE style (non modem)
Each of these styles has a different role. Generally, DTE is for terminals, DCE (modem) is for modems, and DCE (non-modem) is obsolete.
Note: Move pin 6 to pin 8 if you want to change a DCE style (non modem) to a DCE style (modem).
Console and AUX Connectors for Cisco Routers
Connector | Graphic | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RJ-45 |
Signal | RJ-45 Pin | RJ-45 Pin | Signal |
---|---|---|---|
Tx+ | 1 | 1 | Tx+ |
Tx– | 2 | 2 | Tx– |
Rx+ | 3 | 3 | Rx+ |
– | 4 | 4 | – |
– | 5 | 5 | – |
Rx– | 6 | 6 | Rx– |
– | 7 | 7 | – |
– | 8 | 8 | – |
Crossover Cable
In a crossover cable, the first (far left) colored wire at one end of the cable is the third colored wire at the other end of the cable.
RJ-45 Crossover (Ethernet) Cable Pin-outs
Signal | RJ-45 Pin | RJ-45 Pin | Signal |
---|---|---|---|
Tx+ | 1 | 3 | Rx+ |
Tx– | 2 | 6 | Rx– |
Rx+ | 3 | 1 | Tx+ |
– | 4 | 4 | – |
– | 5 | 5 | – |
Rx– | 6 | 2 | Tx– |
– | 7 | 7 | – |
– | 8 | 8 | – |
Rolled Cable
In a rolled cable, the colored wires at one end of the cable are in the reverse sequence of the colored wires at the other end of the cable.
Rolled Cable Pinouts
Signal | RJ-45 Pin | RJ-45 Pin | Signal |
---|---|---|---|
– | 1 | 8 | – |
– | 2 | 7 | – |
– | 3 | 6 | – |
– | 4 | 5 | – |
– | 5 | 4 | – |
– | 6 | 3 | – |
– | 7 | 2 | – |
– | 8 | 1 | – |
Note: CAB-OCTAL-ASYNC, the 8-port RJ-45 adapter that is used with the Cisco 2509, 2510, 2511, and 2512, is the same as a rolled cable.
RJ-45 to DB-9 Female*
This cable is also known as Management Cable.
*Cisco provides this cable with the 600, 800, 1600 and 1700 Series Routers.
Type of Cable for DB-25 Connectors
RS 232 Straight-through Cable
This illustration shows serial cable CAB-R23= (part number 74-0173), which is a general serial cable for all router platforms:
Both Ends of RS 232 Straight-through Cable for DB-25 Connectors
This cable has a female DB-25 connector on one end and a male DB-25 connector on the other end. Either end of the CAB-R23 cable can be the Cisco end or the network end, depending on whether the Cisco router is designated as a DCE device or a DTE device. If the router is designated as a DCE device, the female DB-25 connector is the Cisco end. If the router is designated as a DTE device, the male DB-25 connector is the Cisco end.
Pin-outs for RS 232 Straight Through Cable (DB-25)
Male DTE Pin-outs | Female DTE Pin-outs | ||
---|---|---|---|
25 Pin | Signal | 25 Pin | Signal |
– | – | ||
J2-1 | Shield GND | J2-1 | Shield GND |
J2-2 Shield | TxD – | J2-2 Shield | TxD – |
J2-3 Shield | RxD – | J2-3 Shield | RxD – |
J2-4 Shield | RTS – | J2-4 Shield | RTS – |
J2-5 Shield | CTS – | J2-5 Shield | CTS – |
J2-6 Shield | DSR – | J2-6 Shield | DSR – |
J2-7 Shield | Circuit GND – | J2-7 Shield | Circuit GND |
J2-8 Shield | DCD – | J2-8 Shield | DCD – |
J2-15 Shield | TxC – | J2-15 Shield | TxC – |
J2-17 Shield | RxC – | J2-17 Shield | RxC – |
J2-18 Shield | LTST – | J2-18 Shield | LTST – |
J2-20 Shield | DTR – | J2-20 Shield | DTR – |
J2-24 Shield | TxCE – | J2-24 Shield | TxCE – |
Adapters
You need two types of adapters to connect a PC to a router.
RJ-45-to-DB-9 Adapter
This adapter connects a router to a PC though a COM port.
RJ-45-to-DB-25 Adapter
This adapter connects a router to PC through a serial port.
Cabling and Adapter Setups that Work
Here are the most common ways to console into a router.
Console Connection Combination
Console Port | Cable | Adapter for PC | Adapter for Console Port | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RJ-45 | RJ-45 Rolled | DB-9 / DB-25 | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DB-25 DCE | RJ-45 Rolled | DB-9 / DB-25 | RJ-45-to-DB-25 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Port | RJ-45 Cable | DB-25 Adapter | To Attach |
---|---|---|---|
AUX / Console | Straight | DCE non-modem | TERMINAL |
AUX / Console | Rolled | DTE | TERMINAL |
AUX / Console | Rolled | DCE modem | MODEM |
AUX / Console | RJ-45-to-DB9 | None | TERMINAL |
These are the only setups that work. If you do not have the components you need, use the RJ-45 Component Guide chart to order them.
RJ-45 Port and Adapter Pin-outs
This chart shows the pin-outs for RJ-45 console and AUX ports. The console port does not use RTS/CTS.
RJ-45 Port Pin-outs
Signal | Console Port (DTE) | RJ-45 Rolled Cable | Adapter | Adapter | Signal |
---|---|---|---|---|---|
RJ-45 | RJ-45 Pin | DB-9 Pin | DB-25 Pin | ||
CTS | 1 | 8 | 7 | 4 | RTS |
DTR | 2 | 7 | 4 | 20 | DSR |
TxD | 3 | 6 | 3 | 2 | RxD |
GND | 4 | 5 | 5 | 7 | GND |
GND | 5 | 4 | 5 | 7 | GND |
RxD | 6 | 3 | 2 | 3 | TxD |
DSR | 7 | 2 | 6 | 8 | DTR |
RTS | 8 | 1 | 8 | 5 | CTS |
DB-25 Console and AUX Port Pin-outs
Console Port Signals
Pin | Signal | Direction | Description |
---|---|---|---|
1 | GND | – | Ground |
2 | TxD | Receive Data | |
6 | DSR | —> | Data Set Ready (always on) |
7 | GND | – | Ground |
8 | DCD | —> | Data Carrier Detect (always on) |
Note: The console port does not support modem control or hardware flow control.
Auxiliary Port Signals
Pin | Signal | Direction | Description |
---|---|---|---|
2 | TxD | —> | Transmit Data |
3 | RxD | Request To Send (used for hardware control) | |
5 | CTS |
Note: The auxiliary port supports hardware flow control and modem control.
Console Cable Kit
A console cable kit is provided with your router. Use this kit when you connect your router to a PC or a terminal.
The console cable kit contains these items:
RJ-45-to-RJ-45 console cable (blue)
RJ-45-to-DB-25 adapter (gray)
RJ-45-to-DB-9 adapter (gray)
Note: The Cisco 7200 Series and Cisco 7301 are not shipped by default with a console cable kit. If a console cable is required, order an accessory kit (part number: ACS-2500ASYN).
RJ-45-to-RJ-45 console cable | RJ-45-to-DB-25 adapter | RJ-45-to-DB-9 adapter | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Catalog Part Number | Catalog Description | Label | Shielded? |
---|---|---|---|---|
DTE | CAB-500DTF= | DB-25 CONNECTOR, DTE FEMALE | 29-0810-01/29-DTF-01 | no |
DTE | CAB-500DTM= | DB-25 CONNECTOR, DTE MALE | no | |
modem | CAB-25AS-MMOD= | CABLE CONN-MODEM TO RJ45 SHLD | yes | |
modem | CAB-MMOD= | ADP,RJ45/DSUB | 29-0881-01/29-MMOD-01 | no |
DCE | CAB-500DCF= | DB-25 CONNECTOR, (non modem) DCE FEMALE | 29-0809-01/29-DCF-01 | no |
DCE | CAB-500DCM= | DB-25 CONNECTOR,(non modem) DCE MALE | 29-0808-01/29-DCM-0129- 0808-01/29-DCM-01 | no |
NA | Rolled Cable | CABASY,RJ45 ROLLED, MODULAR | 72-0876-01/CAB-500RJ | NA |
NA | Straight Cable | –not in catalog– | 31-0756-01 | NA |
Cable for DB-25/DB-9 Connection | ||||
NA | Depends on the router* | RJ-45 to DB-9 female an all in one cable | 72-3383-01 | NA |
NA | CAB-R23= | RS 232 Straight-through Cable | – | NA |
NA | Depends on the router* | DB-9 Male to DB-25 male for Modem connection | 29-4043-01 | NA |
The first seven entries are DB-25 connectors, and the last two are RJ-45 cables. Connectors are described in terms of their sex and their role. For example, an FDTE is a female DTE style connector, an MMOD is a male modem style connector, and so on. Remember, you need shielded cables in order to run at 115.2 kbps.
Источник