Кабель Ubiquiti TOUGHCable Pro TC-PRO
Цена с учетом НДС
Варианты
+ | цена | наличие | + | + |
TOUGHCable Carrier | 15100 | ||||| | ||
TOUGHCable Carrier (1м) | 110 | |||| | ||
TOUGHCable Pro | 14800 | |||
TOUGHCable Pro (1м) | 90 | ||||| | ||
Cable UC-C6-CMP | 24500 | |||
Cable UC-C6-CMR | 17400 | |||
UISP Cable Pro | 15500 | | | ||
UISP Cable Carrier | 0 | |||
PowerCable | 0 | |||
FiberModule MM-1G | 1850 | ||||| | ||
UniFi Direct Attach Copper Cable SFP+ 1m | 2400 | |||
UF-RJ45-1G | 2000 | ||||| | ||
UniFi Direct Attach Copper Cable SFP+ 2m | 2500 | ||||| | ||
UF-GP-C+ | 7300 | |||
FiberModule MM-10G | 3950 | | | ||
UniFi Direct Attach Copper Cable SFP+ 3m | 2750 | |||
UF-GP-B+ | 6500 | |||
FiberModule SM-10G-S | 15500 | ||||| | ||
FiberModule SM-10G | 8690 | | | ||
FiberModule SM-1G-S | 2500 | ||||| | ||
FC-SM-100 | 5800 | |||
FC-SM-200 | 8630 | |||
FC-SM-300 | 11590 | |||
UFiber Splitter UF-SPLITTER-4 | 0 | |||
UFiber Splitter UF-SPLITTER-8 | 0 | |||
UFiber Splitter UF-SPLITTER-16 | 0 | |||
UFiber Splitter UF-SPLITTER-32 | 0 | |||
UFiber Adapter APC | 0 | |||
Ethernet Patch Cable | 0 |
Экранированный ToughCable Pro — это кабель промышленного класса категории 5е, предназначенный для работы в неблагоприятных погодных условиях. Так, надежный экран защищает проводники от внешних помех и наводок, а за отвод статики отвечает дополнительные неизолированные жилы. Все это позитивно сказывается на качестве передаваемых данных, так как риск искажения сигнала при его прохождении по кабелю снижается.
Рассматриваемая витая пара разрабатывалась инженерами компании Ubiquiti специально для того, чтобы обеспечить максимальную эффективность взаимодействия с оборудованием компании.
Характеристики TC-PRO
Кабель | Категория 5e, экранированный |
Длина | 1000 футов (304.8 м) |
Ethernet | До 1Гбит/c |
Материал проводника | Медь |
Диаметр проводника | 0.500 ± 0.005 мм |
Тип изоляции | Solid PE |
Толщина изоляции | Средняя: 0.26 мм, Минимальная: 0.25 мм |
Диаметр изоляции | 1.04 ± 0.03 mm |
Разделение (обёртка полиэстером) | Толщина: 0.025 мм, Протяженность: 20 мм |
Защита от перекрёстных помех | Нет |
Защита кабеля (алюминиевая фольга) | Толщина: 0.060 мм, Протяжённость: 18 мм |
Жила для заземления | Да |
Материал оболочки | PE |
Толщина оболочки | Средняя: 0.50 мм, Минимальная: 0.46 мм |
Наружный диаметр оболочки | 6.0 ± 0.30 мм |
Цвет оболочки | Серый |
Стандарт | ISO/IEC 11801, TIA/EIA568B.2 |
Частота (МГц) | Затухание несогласованности (дБ) мин. | Затухание (дБ/100 м) | Соотношение NEXT1/PNEXT2 (дБ) | Защищенность на ближнем конце (параметр ACR)3 | Соотношение ELFNEXT4/PSELFEXT5 |
1 | 17.0 | 2.03 | 62.30 | 60.30 | 60.75 |
4 | 18.8 | 4.04 | 53.26 | 49.20 | 48.71 |
8 | 19.7 | 5.76 | 48.75 | 43.00 | 42.69 |
10 | 20.0 | 6.46 | 47.30 | 40.80 | 40.75 |
16 | 20.0 | 8.24 | 44.30 | 36.10 | 36.67 |
20 | 20.0 | 9.26 | 42.78 | 33.50 | 34.73 |
25 | 19.3 | 10.41 | 41.33 | 30.90 | 32.79 |
31.25 | 18.6 | 11.72 | 39.87 | 28.20 | 30.86 |
62.5 | 16.5 | 16.99 | 35.36 | 18.40 | 24.83 |
100 | 15.1 | 21.97 | 32.29 | 10.30 | 20.75 |
150 | 13.80 | 23.40 | 18.60/30.30 | 8.30 | 17.60/18.50 |
1 Переходное затухание на ближнем конце.
2 Переходное затухание на ближнем конце, учитывающее эффект влияния всех пар на одну. Рассчитывается по результатам отдельных измерений.
3 Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на ближнем конце и затухания сигнала в тракте передачи. Имеет сильную зависимость от частоты.
4 Защищенность на дальнем конце. Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на дальнем конце и затухания сигнала в тракте передачи.
5 Защищенность на дальнем конце модели суммарной мощности. Параметр, численно равный разности суммарного переходного затухания на дальнем конце и затухания сигнала в тракте передачи.
Источник
Кабель Ubiquiti TOUGHCable Carrier TC-CARRIER
Цена с учетом НДС
Варианты
+ | цена | наличие | + | + |
TOUGHCable Carrier | 15100 | ||||| | ||
TOUGHCable Carrier (1м) | 110 | |||| | ||
TOUGHCable Pro | 14800 | |||
TOUGHCable Pro (1м) | 90 | ||||| | ||
Cable UC-C6-CMP | 24500 | |||
Cable UC-C6-CMR | 17400 | |||
UISP Cable Pro | 15500 | | | ||
UISP Cable Carrier | 0 | |||
PowerCable | 0 | |||
FiberModule MM-1G | 1850 | ||||| | ||
UniFi Direct Attach Copper Cable SFP+ 1m | 2400 | |||
UF-RJ45-1G | 2000 | ||||| | ||
UniFi Direct Attach Copper Cable SFP+ 2m | 2500 | ||||| | ||
UF-GP-C+ | 7300 | |||
FiberModule MM-10G | 3950 | | | ||
UniFi Direct Attach Copper Cable SFP+ 3m | 2750 | |||
UF-GP-B+ | 6500 | |||
FiberModule SM-10G-S | 15500 | ||||| | ||
FiberModule SM-10G | 8690 | | | ||
FiberModule SM-1G-S | 2500 | ||||| | ||
FC-SM-100 | 5800 | |||
FC-SM-200 | 8630 | |||
FC-SM-300 | 11590 | |||
UFiber Splitter UF-SPLITTER-4 | 0 | |||
UFiber Splitter UF-SPLITTER-8 | 0 | |||
UFiber Splitter UF-SPLITTER-16 | 0 | |||
UFiber Splitter UF-SPLITTER-32 | 0 | |||
UFiber Adapter APC | 0 | |||
Ethernet Patch Cable | 0 |
Экранированный промышленный кабель категории 5е ToughCable Carrier — это надежная витая пара, оптимизированная под использование для построения магистральных сетевых соединений. Инженеры компании Ubiquiti разрабатывали данную модель с целью создать помехоустойчивую среду передачи данных. Как результат, кабель включает в себя не только изолированные проводники, но и экранированный разделитель, который исключает возникновение взаимопомех.
Другим интересным решением стало включение дополнительного неэкранированного провода, служащего грозозащитой.
ToughCable Carrier отлично совместим со всеми устройствами Ubiquiti, и при этом предоставляет более качественный сигнал по сравнению с обычной витой парой.
Характеристики TC-CARRIER
Кабель | Категория 5e, экранированный |
Длина | 1000 футов (304.8 м) |
Ethernet | До 1 Гбит/c |
Материал проводника | Медь |
Диаметр проводника | 0.500 ± 0.005 мм |
Тип изоляции | Solid PE |
Толщина изоляции | Средняя: 0.295 мм, Минимальная: 0.29 мм |
Диаметр изоляции | 1.16 ± 0.02 мм |
Разделение(обёртка полиэстером) | Толщина: 0.025 мм, Протяженность: 20 мм |
Защита от перекрёстных помех | LDPE: 4.2*0.3 мм |
Защита кабеля(алюминиевая фольга) | Толщина: 0.060 мм, Протяжённость: 20 мм |
Жила для заземления | Да |
Вторичная защита кабеля | 16*8*0.16AA ;Плотность: 95% |
Материал оболочки | PE |
Толщина оболочки | Средняя: 0.52 мм, Минимальная: 0.46 мм |
Наружный диаметр оболочки | 6.8 ± 0.30 мм |
Цвет оболочки | Серый |
Стандарт | ISO/IEC 11801, TIA/EIA568B.2 |
Частота (МГц) | Затухание несогласованности (дБ) мин. | Затухание (дБ/100 м) | Соотношение NEXT1/PNEXT2 (дБ) | Защищенность на ближнем конце (параметр ACR)3 | Соотношение ELFNEXT4/PSELFEXT5 |
1 | 18.0 | 1.93 | 65.30 | 60.30 | 61.00 |
4 | 19.9 | 3.90 | 56.27 | 49.20 | 48.96 |
8 | 20.7 | 5.50 | 51.75 | 43.00 | 42.94 |
10 | 21.0 | 6.30 | 50.30 | 40.80 | 41.00 |
16 | 21.0 | 8.00 | 47.24 | 36.10 | 36.92 |
20 | 21.0 | 9.00 | 45.78 | 33.50 | 34.98 |
25 | 20.3 | 10.20 | 44.33 | 30.90 | 33.04 |
31.25 | 19.5 | 11.50 | 42.88 | 28.20 | 31.10 |
62.5 | 19.0 | 16.70 | 38.36 | 18.40 | 25.08 |
100 | 18.3 | 21.70 | 35.30 | 10.30 | 21.00 |
200 | 16.5 | 32.20 | 30.78/27.78 | 7.60 | 17.78/14.98 |
1 Переходное затухание на ближнем конце.
2 Переходное затухание на ближнем конце, учитывающее эффект влияния всех пар на одну. Рассчитывается по результатам отдельных измерений.
3 Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на ближнем конце и затухания сигнала в тракте передачи. Имеет сильную зависимость от частоты.
4 Защищенность на дальнем конце. Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на дальнем конце и затухания сигнала в тракте передачи.
5 Защищенность на дальнем конце модели суммарной мощности. Параметр, численно равный разности суммарного переходного затухания на дальнем конце и затухания сигнала в тракте передачи.
Источник