Экранированный кабель ubiquiti toughcable

Кабель Ubiquiti TOUGHCable Pro TC-PRO

Цена с учетом НДС

Варианты

Сравнение: TOUGHCable Pro
+ описание цена наличие + бренд + !outpTtle_p0!
Бухта витой пары TOUGHCable Carrier 15100 ||||| Ubiquiti
TOUGHCable Carrier (1м) 110 |||| Ubiquiti
Экранированная витая пара в черной оплетке TOUGHCable Pro 14800 Ubiquiti
TOUGHCable Pro (1м) 90 ||||| Ubiquiti
Cable UC-C6-CMP 24500 Ubiquiti
Cable UC-C6-CMR 17400 UniFi
UISP Cable Pro 15500 | Ubiquiti
UISP Cable Carrier 0 Ubiquiti
PowerCable 0 Ubiquiti
FiberModule MM-1G 1850 |||||
UniFi Direct Attach Copper Cable SFP+ 1m 2400 UniFi
UF-RJ45-1G 2000 |||||
UniFi Direct Attach Copper Cable SFP+ 2m 2500 ||||| UniFi
UF-GP-C+ 7300
FiberModule MM-10G 3950 |
UniFi Direct Attach Copper Cable SFP+ 3m 2750 UniFi
UF-GP-B+ 6500
FiberModule SM-10G-S 15500 |||||
FiberModule SM-10G 8690 |
FiberModule SM-1G-S 2500 |||||
FC-SM-100 5800
FC-SM-200 8630
FC-SM-300 11590
UFiber Splitter UF-SPLITTER-4 0
UFiber Splitter UF-SPLITTER-8 0
UFiber Splitter UF-SPLITTER-16 0
UFiber Splitter UF-SPLITTER-32 0
UFiber Adapter APC 0
Ethernet Patch Cable 0 UniFi

Экранированный ToughCable Pro — это кабель промышленного класса категории 5е, предназначенный для работы в неблагоприятных погодных условиях. Так, надежный экран защищает проводники от внешних помех и наводок, а за отвод статики отвечает дополнительные неизолированные жилы. Все это позитивно сказывается на качестве передаваемых данных, так как риск искажения сигнала при его прохождении по кабелю снижается.

Рассматриваемая витая пара разрабатывалась инженерами компании Ubiquiti специально для того, чтобы обеспечить максимальную эффективность взаимодействия с оборудованием компании.

Характеристики TC-PRO

Кабель Категория 5e, экранированный
Длина 1000 футов (304.8 м)
Ethernet До 1Гбит/c
Материал проводника Медь
Диаметр проводника 0.500 ± 0.005 мм
Тип изоляции Solid PE
Толщина изоляции Средняя: 0.26 мм, Минимальная: 0.25 мм
Диаметр изоляции 1.04 ± 0.03 mm
Разделение (обёртка полиэстером) Толщина: 0.025 мм, Протяженность: 20 мм
Защита от перекрёстных помех Нет
Защита кабеля (алюминиевая фольга) Толщина: 0.060 мм, Протяжённость: 18 мм
Жила для заземления Да
Материал оболочки PE
Толщина оболочки Средняя: 0.50 мм, Минимальная: 0.46 мм
Наружный диаметр оболочки 6.0 ± 0.30 мм
Цвет оболочки Серый
Стандарт ISO/IEC 11801, TIA/EIA568B.2
Частота (МГц) Затухание несогласованности (дБ) мин. Затухание (дБ/100 м) Соотношение NEXT1/PNEXT2 (дБ) Защищенность на ближнем конце (параметр ACR)3 Соотношение ELFNEXT4/PSELFEXT5
1 17.0 2.03 62.30 60.30 60.75
4 18.8 4.04 53.26 49.20 48.71
8 19.7 5.76 48.75 43.00 42.69
10 20.0 6.46 47.30 40.80 40.75
16 20.0 8.24 44.30 36.10 36.67
20 20.0 9.26 42.78 33.50 34.73
25 19.3 10.41 41.33 30.90 32.79
31.25 18.6 11.72 39.87 28.20 30.86
62.5 16.5 16.99 35.36 18.40 24.83
100 15.1 21.97 32.29 10.30 20.75
150 13.80 23.40 18.60/30.30 8.30 17.60/18.50

1 Переходное затухание на ближнем конце.

2 Переходное затухание на ближнем конце, учитывающее эффект влияния всех пар на одну. Рассчитывается по результатам отдельных измерений.

3 Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на ближнем конце и затухания сигнала в тракте передачи. Имеет сильную зависимость от частоты.

4 Защищенность на дальнем конце. Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на дальнем конце и затухания сигнала в тракте передачи.

5 Защищенность на дальнем конце модели суммарной мощности. Параметр, численно равный разности суммарного переходного затухания на дальнем конце и затухания сигнала в тракте передачи.

Источник

Кабель Ubiquiti TOUGHCable Carrier TC-CARRIER

Цена с учетом НДС

Варианты

Сравнение: TOUGHCable Carrier
+ описание цена наличие + бренд + !outpTtle_p0!
Бухта витой пары TOUGHCable Carrier 15100 ||||| Ubiquiti
TOUGHCable Carrier (1м) 110 |||| Ubiquiti
Экранированная витая пара в черной оплетке TOUGHCable Pro 14800 Ubiquiti
TOUGHCable Pro (1м) 90 ||||| Ubiquiti
Cable UC-C6-CMP 24500 Ubiquiti
Cable UC-C6-CMR 17400 UniFi
UISP Cable Pro 15500 | Ubiquiti
UISP Cable Carrier 0 Ubiquiti
PowerCable 0 Ubiquiti
FiberModule MM-1G 1850 |||||
UniFi Direct Attach Copper Cable SFP+ 1m 2400 UniFi
UF-RJ45-1G 2000 |||||
UniFi Direct Attach Copper Cable SFP+ 2m 2500 ||||| UniFi
UF-GP-C+ 7300
FiberModule MM-10G 3950 |
UniFi Direct Attach Copper Cable SFP+ 3m 2750 UniFi
UF-GP-B+ 6500
FiberModule SM-10G-S 15500 |||||
FiberModule SM-10G 8690 |
FiberModule SM-1G-S 2500 |||||
FC-SM-100 5800
FC-SM-200 8630
FC-SM-300 11590
UFiber Splitter UF-SPLITTER-4 0
UFiber Splitter UF-SPLITTER-8 0
UFiber Splitter UF-SPLITTER-16 0
UFiber Splitter UF-SPLITTER-32 0
UFiber Adapter APC 0
Ethernet Patch Cable 0 UniFi

Экранированный промышленный кабель категории 5е ToughCable Carrier — это надежная витая пара, оптимизированная под использование для построения магистральных сетевых соединений. Инженеры компании Ubiquiti разрабатывали данную модель с целью создать помехоустойчивую среду передачи данных. Как результат, кабель включает в себя не только изолированные проводники, но и экранированный разделитель, который исключает возникновение взаимопомех.

Другим интересным решением стало включение дополнительного неэкранированного провода, служащего грозозащитой.

ToughCable Carrier отлично совместим со всеми устройствами Ubiquiti, и при этом предоставляет более качественный сигнал по сравнению с обычной витой парой.

Характеристики TC-CARRIER

Кабель Категория 5e, экранированный
Длина 1000 футов (304.8 м)
Ethernet До 1 Гбит/c
Материал проводника Медь
Диаметр проводника 0.500 ± 0.005 мм
Тип изоляции Solid PE
Толщина изоляции Средняя: 0.295 мм, Минимальная: 0.29 мм
Диаметр изоляции 1.16 ± 0.02 мм
Разделение(обёртка полиэстером) Толщина: 0.025 мм, Протяженность: 20 мм
Защита от перекрёстных помех LDPE: 4.2*0.3 мм
Защита кабеля(алюминиевая фольга) Толщина: 0.060 мм, Протяжённость: 20 мм
Жила для заземления Да
Вторичная защита кабеля 16*8*0.16AA ;Плотность: 95%
Материал оболочки PE
Толщина оболочки Средняя: 0.52 мм, Минимальная: 0.46 мм
Наружный диаметр оболочки 6.8 ± 0.30 мм
Цвет оболочки Серый
Стандарт ISO/IEC 11801, TIA/EIA568B.2
Частота (МГц) Затухание несогласованности (дБ) мин. Затухание (дБ/100 м) Соотношение NEXT1/PNEXT2 (дБ) Защищенность на ближнем конце (параметр ACR)3 Соотношение ELFNEXT4/PSELFEXT5
1 18.0 1.93 65.30 60.30 61.00
4 19.9 3.90 56.27 49.20 48.96
8 20.7 5.50 51.75 43.00 42.94
10 21.0 6.30 50.30 40.80 41.00
16 21.0 8.00 47.24 36.10 36.92
20 21.0 9.00 45.78 33.50 34.98
25 20.3 10.20 44.33 30.90 33.04
31.25 19.5 11.50 42.88 28.20 31.10
62.5 19.0 16.70 38.36 18.40 25.08
100 18.3 21.70 35.30 10.30 21.00
200 16.5 32.20 30.78/27.78 7.60 17.78/14.98

1 Переходное затухание на ближнем конце.

2 Переходное затухание на ближнем конце, учитывающее эффект влияния всех пар на одну. Рассчитывается по результатам отдельных измерений.

3 Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на ближнем конце и затухания сигнала в тракте передачи. Имеет сильную зависимость от частоты.

4 Защищенность на дальнем конце. Параметр, фактически являющийся отношением сигнала к шуму от перекрестных наводок. Численно равен разности переходного затухания на дальнем конце и затухания сигнала в тракте передачи.

5 Защищенность на дальнем конце модели суммарной мощности. Параметр, численно равный разности суммарного переходного затухания на дальнем конце и затухания сигнала в тракте передачи.

Источник

Читайте также:  Кабель для соединения usb портов